a technician is running a network above a dropped - ceiling that is also used for ventilation. the cable…

a technician is running a network above a dropped - ceiling that is also used for ventilation. the cable must be twisted - pair and must be capable of gigabit ethernet speeds. which of the following cables should the technician use?\nriser - rated cat 5e\nplenum - rated cat 6a\nriser - rated rg - 58\nplenum - rated multimode fiber
Answer
Explanation:
Step1: Understand cable requirements
The cable is for a network above a dropped - ceiling used for ventilation, needs to be twisted - pair, and support Gigabit Ethernet speeds.
Step2: Analyze each option
Riser - rated Cat 5e is not suitable for ventilation areas as it is not fire - rated for plenum spaces. Plenum - rated Cat 6a is a twisted - pair cable, fire - rated for plenum spaces (ventilation), and can support Gigabit Ethernet speeds. Riser - rated RG - 58 is coaxial cable, not twisted - pair. Plenum - rated multimode fiber is fiber optic, not twisted - pair.
Answer:
Plenum - rated Cat 6a